Introduzione

Solder bridges are an inevitable occurrence during the soldering process. This guide will show you how to fix a solder bridge and test your circuit after the fix.

A solder bridge can lead to serious damage to your device in the form of a short. A short is when too much current passes through a component, which can lead to device failure. This guide shows how to prevent a particularly dangerous short by clearing a solder bridge between the power and ground rails on a circuit board.

This guide involves the use of high temperatures when desoldering and soldering connections, so take appropriate precautions when the soldering iron is operating. You may need to repeat steps as necessary due to the nature of the desoldering and soldering process.

If you are new to soldering and desoldering, review the How to Solder and Desolder Connections guide.

  1. WHEcoLFTrBUpAASR
    • Set the soldering iron to 300 F (150 C) and wait for the iron to heat up to the desired temperature.

    • Depending on specifications of the soldering iron, it should take between 25-80 seconds for soldering iron to reach desired temperature.

    • The soldering iron tip will be very hot! Be careful when handling the soldering iron during operation.

    • Different solder may have different melting points. Refer to any documentation provided with your solder to determine the recommended temperature.

    • Avoid setting the soldering iron to very high temperatures and stay within your solder's specifications. Prolonged exposure to high temperatures can lead to component or board damage.

  2. IRhwodynTSeUPcUj
    IRhwodynTSeUPcUj
    ZaOR1qpoIFTGqSLC
    b1fClTfHK4bJHPZs
    • Locate the solder bridge on the circuit board.

    • A solder bridge typically bridges two separate contact points (rails).

    • A multimeter can be used here to check for continuity (a short).

    • Apply the solder wick to the affected area.

  3. OpOddaGMuGTgjTJN
    OpOddaGMuGTgjTJN
    G5qiLqVTRZgsWlKA
    • Place the solder wick on top of the solder bridge and heat the wick using the soldering iron by pressing on top of the affected area.

    • The solder wick will be very hot! Avoiding touching the area of the wick near the soldering iron.

    • Continue to apply pressure with the soldering iron to the solder bridge until the solder is melted and absorbed by the wick.

    • A soldering flux can also be used here to aid in the desoldering process by reducing oxide films.

  4. 51UVAig6DShXuElp
    51UVAig6DShXuElp
    AQbwWMXNZXCmiQFr
    FHHVnMEbbBfNkQtf
    • Apply the soldering iron to the contact point.

    • Once the contact point is hot, reapply the solder to the contact point.

    • The repaired area will be very hot! Avoid touching the area being repaired.

    • Continue applying the solder to the contact point until the pin is solidly attached and the rails are separate from each other.

    • Step 7 verifies circuit continuity.

  5. aXdlECY3dkYe2BC3
    aXdlECY3dkYe2BC3
    Q21o33hVRnqI6QKc
    kUcGBEkkaeOXCBOf
    • The soldering iron tip will be very hot! Be careful when handling the soldering iron during its operation.

    • Hold down the dry sponge.

    • While the soldering iron is hot, use a rubbing motion across the sponge to remove excess solder off the soldering iron tip.

  6. ne6ghwgDoZkcNIMf
    • Connect the red (positive) probe to the Voltage and Resistance Socket.

    • Connect the black (negative) probe to the Common/Ground Socket.

    • Set the multimeter knob for continuity testing. This is typically labeled with diode/audio symbols.

    • As shown in the photo, the multimeter will read "OL" if the steps above have been followed properly.

    • To ensure the functionality of the multimeter, touch the two probes together and an audible beeping sound should be emitted.

  7. ZFRCRBVGAE6dU5Es
    • Verify the circuit board does not have any current supplied to it prior to performing the next steps. If a current is present, permanent damage to the multimeter is possible!

    • Connect the black probe to the circuit board rail where one end of the solder bridge was.

    • Connect the red probe to the circuit board rail where the other end of the solder bridge was.

    • If the fix is successful, the multimeter should give a numerical readout on the multimeter screen. This means the rails are no longer connected.

    • If the fix was unsuccessful, the multimeter should read "OL" on the screen, indicating an open circuit.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Steven

Membro da: 19/04/23

217 Reputazione

0 commenti