Introduzione
Use this guide to replace the water inlet valve assembly on your LG refrigerator model LFX25973.
The water inlet valve assembly controls the flow of water to the dispenser and also to the ice makers.
If it fails, you may experience the following:
- Leaking and puddles on the floor near the refrigerator
- Water freezing on the bottom of your freezer
- Ice in your in-door dispenser freezing up and not dispensing
- No ice produced, or no water dispensed if the valve refuses to open at all
Strumenti
-
-
Unplug your refrigerator before you begin your repair.
-
Condenser Fan Motor
-
Compressor Motor and Thermal Overload Device
-
Water Supply Valve Assembly
-
-
-
Use a Phillips screwdriver to remove the six 14.5 mm‑long screws securing the condenser cover to the rear of the refrigerator.
-
-
-
Use a Phillips screwdriver to remove the 16.5 mm‑long screw securing the water inlet valve assembly.
-
-
-
Pull the water inlet valve assembly out of the refrigerator for better access to electrical connections and water tubing connections.
-
-
-
Squeeze and pull downward the remaining water inlet valve assembly connector to disconnect it.
-
-
-
Use long nose pliers to pull and remove the locking clip from the smaller white tubing connector.
-
-
-
Use your fingers to squeeze the flange surrounding the small white water tube toward the valve to release the tube.
-
While you squeeze the flange, pull the tubing straight out of the connector.
-
-
-
For the first solenoid, test the resistance between the red and blue wires on the white connector.
-
Repeat the test on the yellow connector for the other solenoid.
-
To test the flow meter, test the resistance between the red and black wires on the white connector.
-
To reassemble your device, follow these instructions in reverse order.
Take your e-waste to an R2 or e-Stewards certified recycler.
Repair didn’t go as planned? Try some basic troubleshooting, or ask our Answers community for help.