Introduzione
Strumenti
- 
                  
                  
- 
            
Check the nozzle and bed temperature after power on the machine. Both temperature should be in between 30 to 40 degree before preheat. It is the room temperature.
 - 
            
If the temperature showing is below or too much above the room temperature, that means that any problem in heater or thermistor.
 
 - 
            
 - 
                  
                  
- 
            
Remove the thermistor connection from the printer board of the nozzle.Remove the wire connector of the thermistor.
 - 
            
Take a multimeter and connect in the thermistors two leg by putting the multimeter knob into resistance value.
 - 
            
If the thermistor is showing a value of above 60 ohm means, it is working. Else you have to change the thermistor and connect it back in the same way. And go to next step.
 
 - 
            
 - 
                  
                  
- 
            
Take the connecting wire of thermistor with connector at one end.
 - 
            
Take the multimeter, connect the prob of multimeter on the two ends of the wire and also go for continuity test option in the multimeter.
 - 
            
If it is having continuity, the multimeter will produce a beep sound, else we can understand the wire has to be changed.
 
 - 
            
 - 
                  
                  
- 
            
After checking these things , reconnect the thermistor connection.
 - 
            
Now go to prepare
 - 
            
click preheat
 
 - 
            
 - 
                  
                  
- 
            
Go to main menu, you can see the temperature is increasing or not.
 - 
            
If it is incresing, it means the nozzle is working.
 
 - 
            
 
To reassemble your device, follow these instructions in reverse order.