Introduzione

This is a guide to fix base station 2.0.

  1. CcWRwAF54ih6uu4G
    CcWRwAF54ih6uu4G
    XDxKicPRyAJehfc1
    • Score the front plastic.

    • Use the soldering iron to cut part of it until you can open it with pliers.

  2. QSlvRGcqBPNVvWwM
    QSlvRGcqBPNVvWwM
    YJvoLsSqGJCtHOxs
    • The top piece has a slop ramp and it is hard to get off.

  3. GMRgxUfHbErsQDql
    • Use a T8 screwdriver to remove the four screws that are marked with a blue circle.

  4. fDgxY1UCeldZBbUl
    • It is contact pins.

    • Use a T8 screwdriver.

  5. oRLPaSLafINWNx2p
    • Use needle-nose pliers to pry out the piece marked by the blue circle.

  6. 6j4LIVTASF2ySuiU
    • Line up the flat sides.

    • Then add hot glue around the diode case.

  7. r4UjafaQhRIj1xBx
    • Very small wires.

  8. ncbeo2S1XDUwvXHD
    • Black PL1

    • Red PL2

    • White PL3

  9. 5OBDcaoJMdAUJNmU
    5OBDcaoJMdAUJNmU
    peFRGdxB5ZCXP6GX
    rLKFeA1MA6gO6ABK
    • Follow start steps in reverse.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Omegakitty

Membro da: 10/06/22

211 Reputazione

6 commenti

Can you use HLD830030N5T, 5,6mm TO18 30mW 830nm Laser diodes as replacement or is the wattage different?
Thank you for the Info that the 1.0 Laser works in the 2.0 Variant!

Johannes Steinchen -

TLDR, no you need 200mw to replace it.

The wattage for a base station laser is 200mW 830nm. With a 30mW I would expect the laser to immediately burn out because of constant current output.

Omegakitty -

Thank you very much!

Johannes Steinchen -

by any chance could you send a link to that exact laser please and thank you

xen isy -

for instance would this work?

https://www.ebay.com/itm/166018393905?ch...

xen isy -

Yes, that would work

Omegakitty -